sgp130 concentrations Search Results


94
R&D Systems sgp130 concentrations
Exaggeration of IL-6, sIL-6R and <t>sgp130.</t> The figure displays individual time course ( left ) and corresponding boxplots ( right ) of perioperative levels of IL-6, sIL-6R and <t>sgp130</t> levels. The lines on the left are displayed on a a logarithmic scale. Asterisks (*) mark significant differences compared to baseline at p less than 0.05. In the boxplots, the lower boundary of the box indicates the 25th percentile, a black line within the box marks the median, and the upper boundary of the box indicates the 75th percentile. Whiskers above and below the box indicate the 10th and 90th percentiles. Points (°) above and below the whiskers indicate outliers outside the 10th and 90th percentiles (IL-6 outliers above 1200 pg/mL are not shown). Red, blue and green lines indicate IL-6, sIL-6R and sgp130 levels, respectively. Abbreviations: CPB, cardiopulmonary bypass; POD, postoperative day; sgp130, <t>soluble</t> <t>glycoprotein</t> <t>130;</t> sIL-6R, soluble interleukin-6 receptor.
Sgp130 Concentrations, supplied by R&D Systems, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sgp130+concentrations/Human+IL-6R+alpha+Quantikine+ELISA+Kit/pmc08836792-92-6-32
Average 94 stars, based on 1 article reviews
sgp130 concentrations - by Bioz Stars, 2026-09
94/100 stars
  Buy from Supplier

93
R&D Systems sgp130 elisa kit
Figure 2: The levels of serum IL-6 and its receptors are similar in patients with SIRS or sepsis. (A) Serum concentration of IL-6 in healthy volunteers (n = 8), patients with SIRS (n = 7) and patients with sepsis (n = 12). (B) Mean fluorescence intensity (MFI) of the IL-6 membrane receptor (mIL-6R) on peripheral blood monocytes (FSCmed SSCmed CD45+ CD14+) of healthy volunteers (n = 9), patients with SIRS (n = 7) and patients with sepsis (n = 11). (C) Serum concentration of the soluble IL-6 receptor (sIL-6R) in healthy volunteers (n = 5), patients with SIRS (n = 8) and patients with sepsis (n = 11). (D) Serum concentration of the <t>soluble</t> <t>gp130</t> receptor <t>(sgp130)</t> in healthy volunteers (n = 7), patients with SIRS (n = 16) and patients with sepsis (n = 16). Graphs represent individual data (each symbol represents data from one individual), mean and standard error of the mean. ns, not significant, **P < 0.01, ***P < 0.001, Kruskal–Wallis test with Dunn’s multiple comparisons test.
Sgp130 Elisa Kit, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sgp130+concentrations/Human+sgp130+DuoSet+ELISA/pm35647912-57-35-38
Average 93 stars, based on 1 article reviews
sgp130 elisa kit - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

93
R&D Systems systems q6000b dr600
Figure 2: The levels of serum IL-6 and its receptors are similar in patients with SIRS or sepsis. (A) Serum concentration of IL-6 in healthy volunteers (n = 8), patients with SIRS (n = 7) and patients with sepsis (n = 12). (B) Mean fluorescence intensity (MFI) of the IL-6 membrane receptor (mIL-6R) on peripheral blood monocytes (FSCmed SSCmed CD45+ CD14+) of healthy volunteers (n = 9), patients with SIRS (n = 7) and patients with sepsis (n = 11). (C) Serum concentration of the soluble IL-6 receptor (sIL-6R) in healthy volunteers (n = 5), patients with SIRS (n = 8) and patients with sepsis (n = 11). (D) Serum concentration of the <t>soluble</t> <t>gp130</t> receptor <t>(sgp130)</t> in healthy volunteers (n = 7), patients with SIRS (n = 16) and patients with sepsis (n = 16). Graphs represent individual data (each symbol represents data from one individual), mean and standard error of the mean. ns, not significant, **P < 0.01, ***P < 0.001, Kruskal–Wallis test with Dunn’s multiple comparisons test.
Systems Q6000b Dr600, supplied by R&D Systems, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/sgp130+concentrations/Human+IL-6+QuantiGlo+ELISA+Kit/pmc06865852-23-11-10
Average 93 stars, based on 1 article reviews
systems q6000b dr600 - by Bioz Stars, 2026-09
93/100 stars
  Buy from Supplier

Image Search Results


Exaggeration of IL-6, sIL-6R and sgp130. The figure displays individual time course ( left ) and corresponding boxplots ( right ) of perioperative levels of IL-6, sIL-6R and sgp130 levels. The lines on the left are displayed on a a logarithmic scale. Asterisks (*) mark significant differences compared to baseline at p less than 0.05. In the boxplots, the lower boundary of the box indicates the 25th percentile, a black line within the box marks the median, and the upper boundary of the box indicates the 75th percentile. Whiskers above and below the box indicate the 10th and 90th percentiles. Points (°) above and below the whiskers indicate outliers outside the 10th and 90th percentiles (IL-6 outliers above 1200 pg/mL are not shown). Red, blue and green lines indicate IL-6, sIL-6R and sgp130 levels, respectively. Abbreviations: CPB, cardiopulmonary bypass; POD, postoperative day; sgp130, soluble glycoprotein 130; sIL-6R, soluble interleukin-6 receptor.

Journal: Journal of Clinical Medicine

Article Title: Characteristics of Interleukin-6 Signaling in Elective Cardiac Surgery—A Prospective Cohort Study

doi: 10.3390/jcm11030590

Figure Lengend Snippet: Exaggeration of IL-6, sIL-6R and sgp130. The figure displays individual time course ( left ) and corresponding boxplots ( right ) of perioperative levels of IL-6, sIL-6R and sgp130 levels. The lines on the left are displayed on a a logarithmic scale. Asterisks (*) mark significant differences compared to baseline at p less than 0.05. In the boxplots, the lower boundary of the box indicates the 25th percentile, a black line within the box marks the median, and the upper boundary of the box indicates the 75th percentile. Whiskers above and below the box indicate the 10th and 90th percentiles. Points (°) above and below the whiskers indicate outliers outside the 10th and 90th percentiles (IL-6 outliers above 1200 pg/mL are not shown). Red, blue and green lines indicate IL-6, sIL-6R and sgp130 levels, respectively. Abbreviations: CPB, cardiopulmonary bypass; POD, postoperative day; sgp130, soluble glycoprotein 130; sIL-6R, soluble interleukin-6 receptor.

Article Snippet: Quantitative measurements of IL-6, sIL-6R, and sgp130 concentrations were conducted with 96-well plate ELISAs (Human IL-6 Quantikine ELISA Kit, Human IL-6R alpha Quantikine ELISA Kit and Human soluble gp130 Quantikine ELISA Kit, R&D Systems ® Inc., Minneapolis, MN, USA), according to the manufacturer’s protocol.

Techniques:

sIL-6/IL-6 and sIL-6R/sgp130 ratio. The lines show the perioperative levels of ( a ) sIL-6/IL-6 and ( b ) sIL-6R/sgp130 ratio at different time points. Red lines indicate patients with continuously lowest levels, blue lines indicate patients with continuously highest levels and grey lines indicate patients with intermediate levels of perioperative sIL6-R/IL-6 ratio measured between timepoint 3 and 9. Abbreviations: CPB, cardiopulmonary bypass; POD, postoperative day; sgp130, soluble glycoprotein 130; sIL-6R, soluble interleukin-6 receptor.

Journal: Journal of Clinical Medicine

Article Title: Characteristics of Interleukin-6 Signaling in Elective Cardiac Surgery—A Prospective Cohort Study

doi: 10.3390/jcm11030590

Figure Lengend Snippet: sIL-6/IL-6 and sIL-6R/sgp130 ratio. The lines show the perioperative levels of ( a ) sIL-6/IL-6 and ( b ) sIL-6R/sgp130 ratio at different time points. Red lines indicate patients with continuously lowest levels, blue lines indicate patients with continuously highest levels and grey lines indicate patients with intermediate levels of perioperative sIL6-R/IL-6 ratio measured between timepoint 3 and 9. Abbreviations: CPB, cardiopulmonary bypass; POD, postoperative day; sgp130, soluble glycoprotein 130; sIL-6R, soluble interleukin-6 receptor.

Article Snippet: Quantitative measurements of IL-6, sIL-6R, and sgp130 concentrations were conducted with 96-well plate ELISAs (Human IL-6 Quantikine ELISA Kit, Human IL-6R alpha Quantikine ELISA Kit and Human soluble gp130 Quantikine ELISA Kit, R&D Systems ® Inc., Minneapolis, MN, USA), according to the manufacturer’s protocol.

Techniques:

Figure 2: The levels of serum IL-6 and its receptors are similar in patients with SIRS or sepsis. (A) Serum concentration of IL-6 in healthy volunteers (n = 8), patients with SIRS (n = 7) and patients with sepsis (n = 12). (B) Mean fluorescence intensity (MFI) of the IL-6 membrane receptor (mIL-6R) on peripheral blood monocytes (FSCmed SSCmed CD45+ CD14+) of healthy volunteers (n = 9), patients with SIRS (n = 7) and patients with sepsis (n = 11). (C) Serum concentration of the soluble IL-6 receptor (sIL-6R) in healthy volunteers (n = 5), patients with SIRS (n = 8) and patients with sepsis (n = 11). (D) Serum concentration of the soluble gp130 receptor (sgp130) in healthy volunteers (n = 7), patients with SIRS (n = 16) and patients with sepsis (n = 16). Graphs represent individual data (each symbol represents data from one individual), mean and standard error of the mean. ns, not significant, **P < 0.01, ***P < 0.001, Kruskal–Wallis test with Dunn’s multiple comparisons test.

Journal: Clinical and experimental immunology

Article Title: Increased TNF-α production in response to IL-6 in patients with systemic inflammation without infection.

doi: 10.1093/cei/uxac055

Figure Lengend Snippet: Figure 2: The levels of serum IL-6 and its receptors are similar in patients with SIRS or sepsis. (A) Serum concentration of IL-6 in healthy volunteers (n = 8), patients with SIRS (n = 7) and patients with sepsis (n = 12). (B) Mean fluorescence intensity (MFI) of the IL-6 membrane receptor (mIL-6R) on peripheral blood monocytes (FSCmed SSCmed CD45+ CD14+) of healthy volunteers (n = 9), patients with SIRS (n = 7) and patients with sepsis (n = 11). (C) Serum concentration of the soluble IL-6 receptor (sIL-6R) in healthy volunteers (n = 5), patients with SIRS (n = 8) and patients with sepsis (n = 11). (D) Serum concentration of the soluble gp130 receptor (sgp130) in healthy volunteers (n = 7), patients with SIRS (n = 16) and patients with sepsis (n = 16). Graphs represent individual data (each symbol represents data from one individual), mean and standard error of the mean. ns, not significant, **P < 0.01, ***P < 0.001, Kruskal–Wallis test with Dunn’s multiple comparisons test.

Article Snippet: The serum concentrations of IL-1Ra, IL-6/ soluble IL-6 receptor (sIL-6R) complex, and soluble gp130 (sgp130) were measured with the IL-1Ra/IL-1F3 ELISA kit (R&D Systems, Minneapolis, MN), the IL-6/sIL-6R DuoSet ELISA kit (R&D Systems) and the sgp130 ELISA kit (R&D Systems), respectively (detection limits: 18.3, 2.0, and 100 pg/mL).

Techniques: Concentration Assay, Fluorescence, Membrane